10L/MIN.
  8L/MIN.
  5L/MIN.
  3L/MIN.
  2L/MIN.
  Portable 5L/MIN.
  Oxygen Sensor
   Three parameter
   Six parameter
   Six Parameter(Portable)
   Nine parameter
   Mother and Fetal Monitor
   Pulse Oximeter
   Syringe pump
   Infusion pump
   Drip controller
   SXD-1A
   SXD-3A
   SXD-6A
   SXD-12A
   JAC-21355
   JAC-21353
   JAC-672A(plus)
 

WZ-50C6T WZ-50C6
syringe pump(WZ-50C6 and WZ-50C6T)
The specification of syringe pump  
Flow rate 0.1ml/h-1200ml/h(0.1ml/h increments,1ml/h increments                           when rate is over 1000ml/h )50ml syringe
0.1ml/h-600ml/h   (0.1ml/h increments)30ml syringe
0.1ml/h-399.9ml/h(0.1ml/h increments)20ml syringe
Bolus rate 1200ml/h(50 syringe);600ml/h(30ml syringe);399ml/h(20ml syringe)
Occlusion pressure 40N,60N(\10N)
Volumetric accuracy +2%(drive accuracy +1%)
Total volume indication 0.1-9999ml
Preset limited volume 0.1-9999ml
Alarm Near empty,Empty,Syringe dislocated,Syringe plunger disengaged,Malfunction,Forget to operate after power on,Occlusion,Low battery,Battery volume exhausted,AC power failure,Preset limited volume is finished
Operating condition Temperature:-40 to 40≧;Relative humdity:20 to 90%
Transport and
storage condition
Temperature:-40 to 55≧
External dimensions 307(L)〜135(W) 〜128(H)mm
Net weight 2.1kg(include internal battery and I.V.Clamp)
Syringe Syringe size:20ml/30ml/50ml;syringe 13 kinds of disposable brands can be used
OTHER FUNCITONS  
Body weight Mode(only for WZ-50C6T) Fast-injection control
Occlusion Pressure Selected Lock the fast key when infusing
Anti bolus Lock the flow rate keys when infusing
Syringe Brands Selected Audio and Video arlarms
Automatically recognize syringe size AC and DC indicate
Preset limited volume RS 232 port
Total volume indicate Warn of wrong operation
Kvo 500log



WZS-50F6 WZ-50C66T
syringe pump(WZ-50C66T and WZS-50F6)
model
specification
WZS-50F6 WZ-50C66T
Flow rate(ml/h) 10ml syringe:0.1-300 20ml syringe:0.1-399.9
30ml syringe:0.1-600 50ml syringe:0.1-1200
10ml syringe:0.01-300
20ml syringe:0.01-399.9
30ml syringe:0.01-600
50ml syringe:0.01-1200
Occlusion Pressure WZS-50F6:40N,60N(\10N)
WZ50C66T: L:300\100mmHg(40.7 \ 13.3 KPa);
M:500\100mmHg(66.7 \ 13.3 KPa)
H:800\200mmHg(106.7 \ 26.7 KPa)
Bolus rate(ml/h) 1200 (50ml syringe)
600 (30ml syringe )
399 (20ml syringe )
300 (10ml syringe )
1200 (50ml syringe)
600 (30ml syringe )
399.9 (20ml syringe )
300 (10ml syringe )
Total volume indication(ml) 0.1-9999 0.01-9999
Volumetric accuracy +2%(drive accuracy +1%) +\2%(machine perision +\1%)
Alarm Near empty,Empty,Syringe dislocated,Syringe plunger disengaged,Malfunction,Forget to operate after power on,Occlusion,Low battery,Battery volume exhausted,AC power failure,Preset limited volume is finished
Dimension(mm) 345(L)〜186(W) 〜128(H) 307(L)〜135(W) 〜128(H)
Net weigth(Kg) 3.2 2.2
Power supply AC230V/110V,50/60HZ(European Union),DC 12V
The pump can run continuous over 4 hours using internal battery
After it is charged for 16 hours at the rate of 5ml/h
OTHER FUNCITONS  
Body weight Mode(only for WZ-50C6T/WZ-50C66T) Two channel with two governer(only for WZS-50F6)
With drug library(only for WZ-50C66T) Fast-injection control
Occlusion Pressure Selected Lock the fast key when infusing
Anti bolus Lock the flow rate keys when infusing
Syringe Brands Selected Audio and Video alarms
Automatically recognize syringe size AC and DC indicate
Preset limited volume RS 232 port
Total volume indicate Warn of wrong operation
Kvo 500log
Copyright@ Longfian Scitech Co.;Ltd  
Ms.Marina
Ms.Wendy
Ms.Jessica